Our Platform
Commissioning Test Script Software for Mission-Critical Projects
CxScript Pro reads your project documents and generates fully traceable test procedures cited to NETA, NFPA, IEEE, and ASHRAE. Execute in the field with digital signatures and evidence attachments. Enforce gate progression between L1 and L5. Report readiness by system, by level, project-wide.
Starter: 30-day trial. Plus: 14-day trial. Enterprise: demo-to-pilot. Cancel any time during the trial.

Data Centers
Tier II–IV, TPOT planning, N+1 failover

Federal & DoD
UFGS 01 91 00.15 • CUI-aware data classification

Healthcare
NFPA 110 Type 10, Class X, Level 1 essential power
What CxScript Pro Does
From document upload to owner-ready reporting in four steps. Built for the systems and standards commissioning teams actually work with.
Upload Documents
Upload specs, submittals, and sequences. CxScript Pro classifies them automatically and extracts acceptance criteria.
Generate Scripts
CxScript Pro generates project-specific test scripts with standards traceability for any of 19 system types across all 5 levels.
Execute & Track
Run scripts in the field with digital signatures, deficiency logging, and real-time readiness tracking through CxScript Pro.
Report to Owners
CxScript Pro delivers clear dashboards showing what’s ready, what’s in progress, and what needs attention.
CxScript Pro Capabilities
Every feature built from real-world commissioning experience on mission-critical projects.
Specification-Grounded Generation
Reads your uploaded specs, submittals, and sequences of operation and writes tests against them. Not a template library — a project-aware drafting engine.
Standards Traceability
Every step cites the clause. NETA ATS 7.3.1. NFPA 110 §5.6. IEEE C37.20.2. ASHRAE Guideline 0. Auditors do not have to ask twice.
Source-Document Conflict Detection
Before a single test step is written, CxScript Pro flags contradictions between your specs, submittals, and sequences. Conflicts resolved in prep, not at witness testing.
Coverage Analysis
Automated gap detection by category, standard, and equipment. The coverage report is generated — not maintained by hand in a matrix.
FPT & IST Generation
Level-4 Functional Performance Testing and Level-5 Integrated Systems Testing as distinct scripts. IST scenarios include TPOT, cascading failure chains, and cross-system sequences.
Equipment Topology & Relationships
Model parent-child, source-path, redundant-mate, and control-dependency relationships. Failover tests reflect how the real plant is wired.
Digital Field Execution
Signatures, evidence attachments, timestamped step entries, and automatic deficiency logging. Works on tablets over PWA with offline-capable sync.
Script Certification Workflow
PREPARER, REVIEWER, and APPROVER signatures captured on every script. Audit trail retained for owner handover and third-party review.
QC Document Generator & Workbook
Receipt inspections, startup sheets, functional test witness forms, deficiency reports. Compiled into a full QC workbook with compliance profile, document register, and sign-off pages.
Inspection & Test Plans (ITP)
Phase-gated milestones, hold points, and witness expectations generated alongside scripts. No separate ITP authoring pass.
Readiness Dashboards
System-level, level-by-level, and project-wide readiness reporting. Owners see what is actually ready, not a percent-complete number.
Compliance Profiles
Data Center • Commercial Mission Critical • Healthcare • Federal Civilian • DoD UFGS (01 91 00.15) • Custom. Switching profiles re-tunes coverage expectations across the project.
Procore Integration
Pull spec sections and submittals directly from Procore. Document sync keeps source-of-truth on the CM side while CxScript Pro drives commissioning.
CUI / FOUO Data Classification
Classify projects and documents at the right sensitivity level. Export protection and evidence-handling controls align with federal handling expectations.
Air-Gapped On-Premise Deployment
For classified or highly-restricted programs: deploy CxScript Pro on your own hardware with a local LLM. Zero external calls.
Portfolio Readiness View
Multi-project readiness across your book of business. Identify which projects are ahead of schedule, which are at risk, which need escalation.
Auto-Punch from Failed Steps
A failed step becomes a deficiency record automatically, with source context, severity, and readiness impact prepopulated.
OCR for Scanned Submittals
Scanned PDFs, photocopied specs, and image-based drawings pass through OCR before extraction. Legacy documents do not have to be retyped.
Five Commissioning Levels
CxScript Pro supports the complete L1–L5 mission-critical commissioning workflow, from factory witness testing through integrated systems testing.
Factory Witness Testing
Nameplate verification, factory test witnessing, protection device testing, insulation testing, and ship authorization.
Standards: IEEE C37.20.2, IEC 62040-3, ISO 8528
Delivery & Installation
Receiving inspection, structural prerequisites, termination torque, labeling, pre-energization testing, and as-built comparison.
Standards: NETA ATS 7.3.1, NFPA 70, IEC 61439
Pre-Functional / Startup
L1/L2 prerequisite verification, OEM startup checklists, initial energization, setpoint configuration, and BMS I/O verification.
Standards: ASHRAE Guideline 0, NFPA 110, NFPA 72
Functional Performance Testing
Stepped performance testing (25/50/75/100%), alarm verification, interlock logic, mode transitions, redundancy failover, and power quality.
Standards: NETA ATS, IEEE 519, ASHRAE 90.4
Integrated Systems Testing
Total Power Outage Test, N+1 failover, cascading failure chains, fire/life-safety integration, utility restoration, and post-IST audit.
Standards: Uptime Institute Tier Standard, NFPA 110, NFPA 2001
19 System Types in CxScript Pro
Purpose-built templates for every major building system. Each system type includes discipline-specific test steps, acceptance criteria, and standards references.
Electrical
- MV Switchgear
- LV Distribution
- UPS Systems
- PDU / RPP
- STS / ATS
Generator
- Generator Sets
- Generator Auxiliary Systems
Mechanical
- Chillers
- CRAH / CRAC
- Pumps & Pipework
- Cooling Towers
- Fan Coil Units
Fire & Life Safety
- Detection & Alarm
- Suppression Systems
Controls
- BMS Controls
- BMS Sensors & Actuators
Plumbing & Security
- Domestic Water
- Drainage Systems
- Security Access Control
What commissioning test script software does
Commissioning test script software automates the creation of project-specific test procedures that commissioning teams use to verify building systems. Instead of manually drafting scripts from scratch for each project, a test script platform generates structured procedures that include acceptance criteria, standards references, and pass/fail checkpoints tailored to the actual equipment and specifications on a given project.
CxScript Pro goes further than simple template libraries. It reads your uploaded project documents — specifications, submittals, and sequences of operation — and generates test scripts grounded in those actual project requirements. Every test step carries traceability to the relevant ASHRAE, NETA, NFPA, or IEEE standard, giving auditors and owners the documentation rigor they expect.
The result is faster script delivery, higher consistency across engineers and projects, and a documentation set that stands up to scrutiny from owners, authorities having jurisdiction, and third-party reviewers.
CxScript Pro vs. manual workflows
Most commissioning teams still rely on Word documents, Excel spreadsheets, and copy-paste workflows. Here is how CxScript Pro compares.
Use cases by project type
CxScript Pro is built for mission-critical environments but works across any project that demands structured commissioning documentation.
Data Centers
Full L1–L5 workflows for Tier II–IV facilities. TPOT planning, redundancy failover testing, and owner readiness gating.
Learn more →Federal & DoD
UFGS 01 91 00.15 aligned workflows, CUI-aware data classification, and air-gapped on-premise deployment for restricted programs.
Healthcare
Life-safety verification, NFPA 110 essential power testing, and patient-critical HVAC commissioning for hospitals and surgical centers.
Commercial Mission Critical
ASHRAE Guideline 0/1.1 aligned HVAC, lighting controls, building envelope verification, and owner readiness reporting for high-consequence commercial projects.
Frequently asked questions
How does CxScript Pro generate test scripts?
Can I edit scripts after they are generated?
What file formats does CxScript Pro accept?
Does CxScript Pro replace commissioning engineers?
How does CxScript Pro handle different standards?
What is the difference between CxScript Pro and a template library?
What does a CxScript Pro subscription include?
See CxScript Pro in action.
Request a demo or start your 30-day free trial. No card charged for the first 30 days.